BE-LCE
June 29, 2022
TVR
July 1, 2022

TVE

COMPACT SOLUTION FOR LOW AIRFLOW VELOCITIES

Circular air terminal units for use in variable air volume systems at low airflow velocities, even under unfavourable upstream conditions

  • Effective pressure monitoring tubeless via damper blade
  • Effective pressure transmission through effective pressure channel in shaft
  • Terminals with protective cover – no junction boxes required
  • Any direction of flow with dynamic transducer
  • Suitable for airflow velocity of 0.5 – 13 m/s
  • Compact dimensions for use in confined ceiling areas
  • Plug-and-play solution in conjunction with X-AIRCONTROL room control
  • Exact measurement even at low airflow velocities
  • Any installation orientation, even with static transducers
  • Closed blade air leakage to EN 1751, at least Class 3
  • Casing air leakage to EN 1751, Class C
  • Volume flow rate range 1:25

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Circular silencer, types CA, CS or CF, for the reduction of air-regenerated noise
  • Hot water heat exchanger type WL and electric air heater type EL for reheating the airflow
add friend

Description

General Information

Application

  • Circular VAV terminal units for use in ventilation and air conditioning systems
  • For virtually all control, inductor and shut-off tasks in the supply air or extract air area
  • Also for unfavourable upstream conditions at low airflow velocities
  • Closed-loop volume flow control using an external power supply
  • For variable or constant volume flow systems
  • Shut-off via override control by others

Special features

  • High effective pressure signal at a small angle of attack
  • Factory set-up or programming and aerodynamic function testing
  • Volume flow rate can be measured and subsequently adjusted on site; additional adjustment tool may be necessary (depending on the variant of the control component)
  • Effective pressure monitoring tubeless via damper blade
  • Effective pressure transmission through effective pressure channel in shaft
  • Any direction of flow with dynamic transducer
  • Any installation orientation, even with static transducers
  • Suitable for airflow velocity of 0.5 - 13 m/s
  • Compact dimensions for use in confined ceiling areas

Nominal sizes

  • 100, 125, 160, 200, 250, 315, 400

Variants

  • TVE: VAV terminal unit
  • TVE-D: VAV terminal unit with acoustic cladding
  • TVE-FL: VAV terminal unit with flanges on both ends
  • TVE-D-FL: VAV terminal unit with acoustic cladding and flanges on both ends
  • Units with acoustic cladding and/or a circular silencer, types CA, CS or CF, for demanding acoustic requirements

Construction

  • Galvanised sheet steel
  • P1: Powder-coated, silver grey (RAL 7001)
  • A2: Stainless steel

Parts and characteristics

  • Ready-to-commission unit which consists of mechanical parts and control components.
  • Damper blade with integrated measuring unit
  • Shaft with effective pressure channel for measured value transmission
  • Factory-assembled control components complete with wiring
  • Aerodynamic functional testing on a special test rig prior to shipping of each unit
  • Set-up data is given on a label or volume flow rate scale affixed to the unit
  • High control accuracy, even in unfavourable upstream conditions

Attachments

  • EASY controller: Compact unit consisting of controller with potentiometers, effective pressure transducer and actuator
  • Compact controller: Compact unit consisting of controller with potentiometers, effective pressure transducer and actuator
  • Compact controller Modbus: Variant with Modbus RTU interface; plug-and-play solution in conjunction with X-AIRCONTROL room control

Accessories

  • G2: Matching flanges for both ends
  • D2: Double lip seals on both ends (factory fitted)

Useful additions

  • Circular silencers, types CA, CS or CF
  • Heat exchanger type WL
  • Electric air heater type EL

Construction features

  • Circular casing
  • Spigot suitable for circular ducts to EN 1506 or EN 13180
  • Spigots with groove for seal
  • Position of the damper blade indicated externally at position indicator
  • TVE-FL: Flanges to EN 12220
  • Control component can be replaced

Materials and surfaces

Galvanised sheet steel

  • Casing made of galvanised sheet steel
  • Damper blade, effective pressure sensor and shaft made of plastic, PA6, UL94, flame retardant (V-0)
  • Damper blade seal made of plastic, TPU, antimicrobial
  • Plastic plain bearings

Powder-coated construction (P1)

  • Casing made of galvanised sheet steel, surface powder coated, silver grey (RAL 7001)
  • Damper blade, effective pressure sensor and shaft made of plastic, PA6, UL94, flame retardant (V-0)
  • Damper blade seal made of plastic, TPU, antimicrobial
  • Plastic plain bearings

Stainless steel construction (A2)

  • Casing made of stainless steel 1.4301
  • Damper blade, effective pressure sensor and shaft made of plastic, PA6, UL94, flame retardant (V-0)
  • Damper blade seal made of plastic, TPU, antimicrobial
  • Plastic plain bearings

Acoustic cladding

  • Variant with acoustic cladding (-D)
  • Acoustic cladding made of galvanised sheet steel
  • PE ring for the insulation of structure-borne noise
  • Lining is mineral wool

Mineral wool

  • To EN 13501, fire rating Class A1, non-combustible
  • RAL quality mark RAL-GZ 388
  • Non-hazardous to health thanks to being highly biosoluble in accordance with the Ordinance on Hazardous Substances and Note Q of the European Directive (EC) No. 1272/2008

Standards and guidelines

Fulfils the hygiene requirements of

  • EN 16798, Part 3
  • VDI 6022, Sheet 1
  • DIN 1946, Part 4
  • For other applicable standards and guidelines refer to the hygiene certificate

Casing leakage

  • EN 1751, Class C

Closed blade air leakage:

NS 100 – 160

  • EN 1751, Class 3
  • Meets the general requirements of DIN 1946, part 4, with regard to the acceptable closed blade air leakage

NS 200 – 400

  • EN 1751, Class 4
  • Meets the increased requirements of DIN 1946, part 4, with regard to the acceptable closed blade air leakage

Maintenance

  • Maintenance-free as construction and materials are not subject to wear

 

Download

Product Information

 

Brochures

 

Certificates

 

Operation Manuals